Skip to main content Skip to search Skip to main navigation

Filter products

Electric impulse pigeon repellent
Electric impulse pigeon repellent

Electric impulse pigeon repellent Made in Germany! Complete system for 100 running metres consisting of: Stainless steel rod 2.0 mm / 1.5 m long 134 pieces Plastic hump (UV-resistant) 300 pieces Connecting spring V2A 150 pieces Copper clamping sleeve 25 pieces The product The electrical system uses continuous current pulses to effectively prevent pigeons from perching pigeons from perching on cornices, window sills, parapets, etc. The stainless steel rods (ø 2.0 mm) are held by approx. 28 mm high UV-stabilised plastic humps, which are attached with our OttoColl special adhesive. The electrical system is approx. 25 mm wide and prevents pigeons from perching over a maximum width of 100 mm. The principle The current impulse is generated by a current impulse generator. The harmless electric shock is unpleasant for the pigeons and thus prevents them from perching again. The system can optionally be fitted with a lightning protection choke. The assembly At least 2 days should be planned for installation: On the first day, the surface should be cleaned so that it is free of grease and dust. The bumps are glued on at intervals of approx. 30 cm (corresponds to 3 bumps per metre) using our special OttoColl adhesive. It is not necessary to screw on the bumps. On the second day, the stainless steel rods are inserted and the connection to the surge generator is made. The surge generator must be connected on site and should be installed protected from the weather, ideally inside the building. (Please observe the enclosed operating instructions for the surge generator) The connection to the stainless steel rods is made exclusively with the high-insulation cable: power on the approach side, earth on the rear side. In principle, a closed circuit is not necessary. If the system is installed over several storeys, the connection is also made with the insulation cable. The rods are connected to each other using connecting springs. These should only be pushed 50% into the spring so that they have enough air to equalise tension and compression. For longer distances, an expansion loop should be created with the high insulation cable at intervals of 10 metres. Assembly instructions: - The rods must be firmly fixed to the first and last plastic humps in front of and behind the hump holder. - The rods must be able to move horizontally, i.e. the springs to be used should only be placed on the rods for half of the total spring length. - When connecting two rods in front of corners, an additional hump may need to be fitted to provide sufficient support for the wire. Alternatively, you can also use the long wire for the corner area and make the extension in the straight section. Caution: This system should only be installed by trained personnel and connected by an electrician! We accept no liability for malfunctions, faults or damage caused by Installation!

Regular price: €674.18
High insulation cable
High insulation cable

Colour: black, roll of 50 running metres. Resistance: approx. 0.025 Ohm/m Outer diameter: 7 mm Conductor diameter approx. 1.32 mm Conductor cross-section 1 mm²

Regular price: €80.85
Lightning protection choke for electric pigeon defence
Lightning protection choke for electric pigeon defence

This lightning protection choke complies with the VDE 131 standard and protects your surge generator from damage caused by lightning strikes to the electrical system when installed correctly.

Regular price: €43.66
Colle de construction : colle et étanchéifie avec puissance  - Couleur : gris
Structural Adhesive: Bonds + Seals Power - Colour: grey

High-strength, elastic hybrid structural adhesive Contents: 300 ml Packaging: Cartridge Chemical composition: Hybrid polymer Skin formation time (max.): 40 min Skin formation time min./max.: 30–40 min Curing rate / conditions: 3 mm/day / 23°C and 50% relative humidity, moisture-curing Application temperature min./max.: 5 to 40 °C Temperature resistance min./max.: -40 to +90 °C Temperature resistance, short-term max.: 150 °C Temperature resistance, short-term max. / conditions: 150 °C / after 16 hours Volume change max.: 2 % Max. volume change / condition: 2% / according to DIN 52451 Short-term resistance to: mineral oils, fuels, animal fats, animal oils, vegetable fats, vegetable oils Silicone-free: Yes Solvent-free: Yes PVC-free: Yes VOC-free: Yes Isocyanate-free: Yes UV resistance: Yes Applications For structurally bonded joints subject to dynamic stress, as well as seam and joint sealing in bodywork, vehicle and caravan construction, railway carriage and container construction, metal and plant engineering, air conditioning and ventilation duct construction, the food industry and many more. Instructions Surfaces must be clean, dry and free of grease. For pre-treatment, please refer to the optimisation table in the technical data sheet. Cut off the threaded cap, screw on the nozzle and cut to the desired width. Apply the adhesive using a suitable caulking gun. To benefit from the advantages of thick-film bonding, a minimum adhesive thickness of 3 mm is recommended. Further information can be found on the manufacturer’s website

Regular price: €11.69
Surge generator for electric pigeon defence
Surge generator for electric pigeon defence

AKO N 1200 12.5 KV, 1.7 joules in / 1.2 joules out for system lengths up to 3000 running metres.